Institute Instrumentation Centre
How to calculate the 3D and 2D views of XRDML file formats in the High score?
2:23
Institute Instrumentation Centre
What are the Isolines View and Compare View and how to calculate it in high score?
5:46
Institute Instrumentation Centre
How to get Analyzer View in High score?
2:26
Institute Instrumentation Centre
How to do document settings in high score?
3:25
Institute Instrumentation Centre
How to get Crystal structure reports in High score?
1:55
Institute Instrumentation Centre
How to get Anchor scan data, Pattern list and Peak lists in High score?
2:11
Institute Instrumentation Centre
How to calculate the XRD results in high score with the help of XRDML File?
6:02
Institute Instrumentation Centre
How to get Quantification chart in high score from XRDML files.
2:40
Institute Instrumentation Centre
How to do normal search and match function in High score?
1:56
Institute Instrumentation Centre
How to perform restriction search and match function in high score?
4:31
Institute Instrumentation Centre
What are the functions of treatment button on high score menu bar?
5:03
Institute Instrumentation Centre
How to view two XRDML samples patterns in a single waveform?
2:30
Institute Instrumentation Centre
How to do X-axis and Y-axis settings for XRD results in Highscore?
2:37
Institute Instrumentation Centre
How the EDAX software works and how to generate images and reports with the help of this software
15:06
Institute Instrumentation Centre
How the SEM sample holder looks like?
3:49
Institute Instrumentation Centre
How the PUMP and VENT functions done in SEM machine?
11:25
Institute Instrumentation Centre
How to prepare the fiber sample for gold coating and SEM?
6:25
Institute Instrumentation Centre
How to turn ON SEM Machine and its Software's step by step?
6:30
Institute Instrumentation Centre
How to prepare the powder samples for gold coating for SEM Machine?
3:01
Institute Instrumentation Centre
How to create unique ID and passwords for SEM Users?
5:16
Institute Instrumentation Centre
How to mount samples on sample stage and how to insert it in the Machine?
3:29
Institute Instrumentation Centre
Deep discussion of the EDAX Machines and software working.
18:55
Institute Instrumentation Centre
How the SEM navigations and aperture functions works?
4:16
Institute Instrumentation Centre
How the Gold coating done for SEM samples?
7:05
Institute Instrumentation Centre
How to connect and communicate with the SEM and EDAX software?
5:13
Institute Instrumentation Centre
What are the connections and components we have to check before start the SEM?
2:01
Institute Instrumentation Centre
How EDAX works with SEM software to get the images and generate the reports?
5:16
Institute Instrumentation Centre
How to PUM the Struers lectropol-5 Machine before polishing the samples?
7:32
Institute Instrumentation Centre
How to perform cleaning function on the Struers Lectropol-5 Machine for the SEM samples?
6:28
Institute Instrumentation Centre
What are the procedures of changing sample stage in XRD Machine.
5:54
Institute Instrumentation Centre
What are the steps for license activation in high score? How to activate license in high score plus?
3:40
Institute Instrumentation Centre
How to get Anchor scan data? in text documents format.
2:46
Institute Instrumentation Centre
How the Si-Standard sample result looks like?
5:49
Institute Instrumentation Centre
What are the settings required for the pallet type of sample for XRD?
6:45
Institute Instrumentation Centre
How to get the Semi Quant percentage (%) in High score ?
4:03
Institute Instrumentation Centre
How to get the XRD Results from the .XRDML file??
3:47
Institute Instrumentation Centre
How to prepare a Gel sample for XRD?
6:13
Institute Instrumentation Centre
How to perform fast scan sample in Data collector? What are the settings?
8:13
Institute Instrumentation Centre
Which kind of information user can get through the XRD Reference file?
4:58
Institute Instrumentation Centre
What are the default graph settings in Data viewer?? How it is important for XRD??
6:37
Institute Instrumentation Centre
How to compare Multiple XRDML results wave forms in a single worksheet in High score?
3:17
Institute Instrumentation Centre
What is unwanted Radiations? What are the treatment of unwanted Radiations?
8:11
Institute Instrumentation Centre
How to deal with Fluorescent samples?
3:34
Institute Instrumentation Centre
How to prepare the Steel and Aluminum types of samples for XRD?
4:57
Institute Instrumentation Centre
How to generate the Report from the XRDML file with the help of DATA VIEWER?
4:39
Institute Instrumentation Centre
High score plus full calculations explained with the help of PPT.
5:06
Institute Instrumentation Centre
How to generate the .XRDML file through data collector?
2:32
Institute Instrumentation Centre
How to prepare Absolute Scan Program in Data Collector??
3:03
Institute Instrumentation Centre
What is Quantification?? and how its works?
2:48
Institute Instrumentation Centre
How to save Image and ASC file in high score from .XRDML file.
1:47
Institute Instrumentation Centre
How to calculate Position 2thieta, FWHM,D-Spacing & Intensity values in High score for XRDML File.
2:14
Institute Instrumentation Centre
How to disconnect (Turn off/ Shut down) Data Collector from the XRD Machine?
2:00
Institute Instrumentation Centre
How has the Ph.D. setting done in Data Collector? What are the settings used for the Al sample?
2:02
Institute Instrumentation Centre
How breeding function done in Data Collector?? Why it is necessary?
5:08
Institute Instrumentation Centre
How to operate Data Collector Software for XRD Machine??
5:07
Institute Instrumentation Centre
How the Reference Pattern works in high score plus?
4:11
Institute Instrumentation Centre
What is Smoothing, Fourier filter and Insert peaks ? and how it works?
3:36
Institute Instrumentation Centre
How to Search and Delete the peaks in High score plus?
3:40
Institute Instrumentation Centre
How to Determine and Delete the background of the particular sample in High Score plus?
3:01
Institute Instrumentation Centre
How to calculate the Anchor Scan Data File in High score?
3:50
Institute Instrumentation Centre
How to clean and wash the sample holders and all other small components.
3:50
Institute Instrumentation Centre
How to prepare a powder sample on the Zero background sample holder for the XRD?
4:00
Institute Instrumentation Centre
How to prepare the paper type of sample for XRD? Is it possible to do XRD with such kind of samples?
5:00
Institute Instrumentation Centre
How to prepare Powder sample on sample holder for XRD?
4:12
Institute Instrumentation Centre
How High Score works?? and How to calculate the XRD results in High score.
1:48
Institute Instrumentation Centre
How the Data Collector perform the Absolute Scan function of the samples?
5:07
Institute Instrumentation Centre
How Data Collector software work?
4:08
Institute Instrumentation Centre
How to compare the two or more XRDML Results in a single sheet.
5:02
Institute Instrumentation Centre
Introduction of XRD machine hardware parts mainly Jun Air and Chiller.
8:27
Institute Instrumentation Centre
Which Equipment's are used in sample preparation for the XRD machine.
6:37
Institute Instrumentation Centre
How to select and restrict the particular elements with the help of high score periodic table.
6:18
Institute Instrumentation Centre
what are the different types of searches and matches in the high score?
6:11
Institute Instrumentation Centre
How to make small peaks visible and how to crop the wave form in high score.
5:36
Institute Instrumentation Centre
What are the uses of Data Viewer software in XRD Machine.
14:33
Institute Instrumentation Centre
How to perform Search and Match function in the High Score.
13:23
Institute Instrumentation Centre
How to Calculate XRD Results with the help of High Score.
10:38